20
2.6 Entering Calibration Data
WARNING!
WHEN THE SYSTEM IS IN CALIBRATION MODE, AUTOMATIC OVERLOAD CONTROLS ARE
DISABLED. THE CRANE OPERATOR IS RESPONSIBLE FOR PROPER LOADING OF THE CRANE
WHILE PERFORMING CALIBRATION.
To enter the calibration data, it is necessary to put the system in calibration mode. Once in calibration
mode, there is only five (5) seconds to enter the security code sequence.
To enter the calibration mode:
1. Simultaneously press the
TEST
and
SET
buttons. The audible alarm will sound and the user will
be prompted to enter the security code.
2. Enter the security code in the order shown:
3. The system is now in calibration mode and ready to receive calibration data. Use the
Next
and
Prev
buttons to scroll through the following menus:
00 Error codes
–
Displays system information and error codes.
01 Crane Data
–
Used to reset the crane personality data.
02 Dimensions
–
Used to enter the crane geometry dimensions previously recorded.
03 Zero Sensor
–
Used to set the zero point for extension and angle sensors.
04 Span Sensors
–
Used to insert numbers for extension and angle sensors.
05 Swing Potentiometer
–
Used to set the zero point and direction for the swing potentiometer.
06 Pressure
–
Used to calibrate the lift cylinder dimensions and load.
07 Radius/Moment
–
Used to calibrate the radius and moment for the main boom.
08 Boom Deflection
–
Used to calibrate deflection for the main boom and attachments.
09 Head Angle
–
Used to enter boom head angles.
10 Erected Attachments
–
Used to calibrate the erected attachments.
11 Enable Winches
–
Used to enable and disable winches.
12 Digital Inputs
–
Used to view status of digital inputs.
13 Pressure Monitor
–
Used to view cylinder pressures in PSI.
TEST
SET
1
2
3
4
SkyAzúl, Equipment Solutions
www.skyazul.com
301-371-6126