Other settings
This page shows a summary of configuration settings that are not lubrication channel specific. The page can be entered from
the set value display with the
Comm conf
button.
Parameter
Description
Name
The name of the centre, shown on the start display. The maximum length of the name is
10 characters.
Language
The language of the display
Pressure
Pressure display method [bar] or [psi]
Interlock
"
SEP: Each channel has its own interlocking input.
"
COMM: The channels use the same interlocking input from the interlocking input 1
Pump
configuration
"
1 pumping centre, no Dualset: Both lubrication channels use the same pump.
Channels are controlled with shut-off valves. No doubled pumping centre
"
2 pumping centres, no Dualset: Both channels have their own pumping centre. No
doubled pumping centre
"
1 pumping centre, Dualset: Both lubrication channels use the same doubled
pumping centre. Channels are controlled with shut-off valves.
"
2 pumping centres, Dualset: Both channels have their own doubled pumping centre.
Online con.
Connection method to the Online1440 PC software. Can be selected between RS232 or
RS422.
Address
Centre address (1&7) when using the Online1440 PC software.
The settings of this display page can be changed on the password level