29
Display lines
NOTE!
The texts in brackets are examples of display texts.
The first line indicates the selected channel:
"
number (
CH1
= lubrication channel 1)
"
operation mode,
see section 3.4
(
DuoFlex, SG
)
"
name (
Conveyor 1
)
Next, the selected channel is shown:
"
program phase (
Pressuring L1
)
"
in graphic format elapsed time of the program phase (pressuring and interval) in percentages of the set value of the
maximum pressurization time and lubrication cycle. In the Duoflex system, the elapsed time is shown as a percentage of
half a lubrication cycle
"
the duration of the current phase (
s71
)
"
Line 1 pressure display in numbers and graphic format. The graphic presentation is scaled in percentages to the high limit
value for pressure. (
L1 117 bar
, max.
120 bar
)
The following line shows the line 2 pressure in the DuoFlex system correspondingly to line 1.
"
When the lubrication channel is equipped with pressure switches, the pressure will not be presented in numbers. The
switch status can be seen in the graphic:
- blue bar when the switch is closed
- empty bar when the switch is open
On the following line the possible alarm/warning situations, which do not interrupt the channel's lubrication functions, are
displayed:
"
Pump change indication when using the Max-Dualset pumping centre
o
Pump changed: YES 1,
Pump changed to pump 1, master
o
Pump changed: YES 2,
pump changed to pump 2, slave
"
Doser monitoring alarm from Doser Monitor
The indication and warning or alarm triggered by it are reset with the reset button (
reset
) on the right side of the text.
Summary of Contents for ST-1240-GRAPH
Page 17: ...17...
Page 25: ...25 Dimensions...