THERMAL RECEIPT PRINTER
43
On
01
1
Drawer kick-out connector pin 3 status
enabled.
1 -
-
-
Undefined.
2 Off
00
0
Error
status
disabled.
On
04
4
Error status enabled.
3
Off
00
0
Paper roll sensor status disabled.
On
08
8
Paper roll sensor status enabled.
4-7 -
-
-
Undefined.
[Details]
If any of the status items in the table above are enabled, the printer transmits the status when
this command is executed. The printer automatically transmits the status whenever the enabled status
item changes. The disabled status items may change, in this case, because each status transmission
represents the current status.
If all status items are disabled, the ASB function is also disabled.
If the ASB is enabled as a default, the printer transmits the status when the printer data reception and
transmission is possible at the first time from when the printer is turned on.
The following four status bytes are transmitted without confirming whether the host is ready to
receive data. The four status bytes must be consecutive, except for the XOFF code.
Since this command is executed after the data is processed in the receive buffer, there may be a time lag
between data reception and status transmission.
When the printer is disabled by
ESC =
(Select peripheral device), the four status bytes are
transmitted whenever the status changes.
When using
DLE EOT
,
GS
I, or
GS r
, the status transmitted by these commands and ASB status must
be differentiated, according to the procedure in Appendix G,
Transmission Status
Identification
.
GS f n
[Name] Select font for Human Readable Interpretation (HRI) characters
[Format] ASCII GS f
n
Hex 1D 66
n
Decimal 29 102
n
[Range]
n
= 0, 1, 48, 49
[Description] Selects a font for the HRI characters used when printing a bar code.
n
selects a font from the following table:
n
Font
0, 48
Font A (12
24)
1, 49
Font B (9
17)
[Details]
HRI indicates Human Readable Interpretation.
HRI characters are printed at the position specified by
GS H
.
[Default]
n
= 0
[Reference]
GS H
,
GS k