THERMAL RECEIPT PRINTER
26
• The horizontal and vertical motion unit are specified by
GS P
.
• The
GS P
command can change the horizontal (and vertical) motion unit.
However, the value cannot be less than the minimum horizontal movement
amount, and it must be in even units of the minimum horizontal movement
amount.
• In standard mode, the horizontal motion unit is used.
• In page mode, the horizontal or vertical motion unit differs as follows,
depending on the starting point of the printing area:
①
When the starting position is set to the upper left or lower right of the
printable area using
ESC T
, the horizontal motion unit ( x) is used.
②
When the starting position is set to the upper right or lower left of the
printable area using
ESC T
, the vertical motion unit ( y) is used.
[Reference]
ESC $
,
GS P
ESC a n
[Name] Select justification
[Format] ASCII ESC a n
Hex 1B 61 n
Decimal 27 97 n
[Range] 0 <=
n <=
2, 48 <=
n <=
50
[Description] Aligns all the data in one line to the specified position
n selects the justification as follows:
n
Justification
0,48 Left
justification
1, 49
Centering
2, 50
Right justification
[Details]
The command is enabled only when processed at the beginning of the line in
standard mode.
If this command is input in page mode, the printer performs only internal flag
operations.
This command has no effect in page mode.
This command executes justification in the printing area.
This command justifies the space area according to
HT, ESC $
or
ESC \
.
[Default] n = 0
[Example]
ESC c 3 n
[Name] Select paper sensor(s) to output paper end signals
[Format] ASCII ESC c 3
n
Hex 1B 63 33
n
Decimal 27 99 51
n
[Range] 0 <=
n
<=
255
[Description] Selects the paper sensor(s) to output paper end signals