THERMAL RECEIPT PRINTER
24
[Details]
This command affects printing in standard mode. However, the setting is
always effective.
When underline mode is turned on, the printer does not underline 90
clockwise-rotated.
Double-width and double-height commands in 90
rotation mode enlarge
characters in the opposite directions from double-height and double- width
commands in normal mode.
[Default] n = 0
[Reference]
ESC !, ESC
ESC W
x
L
x
H
y
L
y
H
dx
L
dx
H
dy
L
dy
H
[Name] Set printing area in page mode
[Format] ASC II ESC W xL xH yL yH dxL dxH dyL dyH
Hex 1B 57 xL xH yL yH dxL dxH dyL dyH
Decimal 27 87 xL xH yL yH dxL dxH dyL dyH
[Range] 0 <=
xL, xH, yL, yH, dxL, dxH, dyL, dyH <=
255 (except dxL= dxH=0 or dyL= dyH=0)
[Description]
The horizontal starting position, vertical starting position, printing area width,
and printing area height are defined as x0, y0, dx (inch), dy (inch), respectively.
Each setting for the printing area is calculated as follows:
x0 = [( xL + xH
256)
(horizontal motion unit)]
y0 = [( yL + yH
256)
(vertical motion unit)]
dx = [ dxL + dxH
256]
(horizontal motion unit)]
dy = [ dyL + dyH
256]
(vertical motion unit)]
The printing area is set as shown in the figure below.
[Details]
If this command is input in standard mode, the printer executes only internal
flag operation. This command does not affect printing in standard mode.
If the horizontal or vertical starting position is set outside the printable area, the
printer stops command processing and processes the following data as normal
data.
If the printing area width or height is set to 0, the printer stops command
processing and processes the following data as normal data.
This command sets the position where data is buffered to the position specified
by
ESC T
within the printing area.
If (horizontal starting po printing area width) exceeds the printable area,
the printing area width is automatically set to (horizontal printable area -
horizontal starting position).
If (vertical starting po printing area height) exceeds the printable area,
the printing area height is automatically set to (vertical printable area - vertical
starting position).
The horizontal and vertical motion unit are specified by
GS P
. Changing the
horizontal or vertical motion unit does not affect the current printing area.
The
GS P
command can change the horizontal (and vertical) motion unit.
However, the value cannot be less than the minimum horizontal movement
amount, and it must be in even units of minimum horizontal movement amount.