may result in property loss.
Green
—to indicate operation or maintenance instruction.
Electrocution Hazard
This machine is NOT insulated, and NO electrocution protection is available.
Keep away from the power lines and machines according to applicable government regulations
and the instruction below.
Voltage Min. safety distance
(phase to phase) (m)
0V to 50kV 3.05 m
50kV to 200 kV 4.60 m
200kV to 350 kV 6.10 m
350 kV to 500 kV 7.62 m
500 kV to 750 kV 10.67 m
750 kV to 1000 kV 13.72 m
Caution against strong and fitful wind given the possibility of movement of platform, and
swinging and loosening of cables. No operation during lightning and rainstorm.
Keep away from the machine being connected with live cables. No touch by persons on the
ground and NO operation by persons on the platform before the power is cut off.
NO use of the machine as grounding wire during welding.