21
At the parameter setting pages, each parameter is configurable, like: water out temperature for cooling, water
out temperature for heating, and water tank temperature etc.
[Operation Instructions]
(1) At the homepage, it is able to go to the
PARAMETER
page by pressing the Function key no.2
.
(2) At the
Parameter Set
page, by the Left/Right key
select the desired option and then by the Up/
Down key
increase or decrease the setting value which will be continuously changed when
pressing and holding the key.
(3) When the setting is finished, press “
Save
”
and a dialog box will pop up, reminding “
Save settings?
”.
If so, press the OK key
; if not press the Cancel key
to not save this setting.
[Notes]
For those parameter which default value vary by different condition, the value will set to default when the
condition changes.
User Setting
No.
Full Name
Displayed
Name
Range(°C)
Range(°F)
Default
1
Water out
temperature for
cooling
WOT-Cool
7~25°C
[Without underfloor
coil]
18~25°C
[With underfloor coil]
45~77°F
[Without underfloor
coil]
64~77°F
[With underfloor coil]
7°C/45°F[Without
underfloor coil]
18°C/64°F[With
underfloor coil]
2
Water out
temperature for
heating
WOT-Heat
25~60°C[High
temp.]
25~45°C[Normal
temp.]
77~140°F[High
temp.]
77~113°F[Normal
temp.]
45°C/113°F[High temp.]
35°C/95°F[Normal
temp.]
3
Room temperature
for cooling
RT-Cool
18~30°C
64~86°F
24°C/75°F
4
Room temperature
for heating
RT-Heat
18~30°C
64~86°F
20°C/68°F