10
(c) At the “Parameter View” page, it is able to check the set point at the Weather-dependent Mode.
(d) When it is activated, it is allowed to set the room temperature but the set point does not take effective.
However, when it is deactivated, the unit will run according to this set point.
(e) It can be set to “On” or “Off” no matter if the unit is in operation or not, but be activated only when the unit is
in operation.
(f) This mode works only for the air conditioning function.
2.2.10 Holiday Release
In summer or high-temperature season, this function will make the unit pause to run in some specific periods
when the user is out.
[Operation Instructions]
Go to the
FUNCTION
page and locate “
Holiday release
”, then, configure it through the Up/Down key
, “
On
” or “
Off
”.
[Notes]
(a) When it is activated, at the
WEEKLY TIMER
page, it is able to set some week day to “
Holiday release
”. In
this case, the “
Weekly timer
” in this day is ineffective unless it is set to “
Effective
” manually.
(b) This setting will be memorized upon power failure.
2.2.11 Disinfection
This function is intended to sanitize the water tank by raising the water temperature to 70°C under which the
legionella will die immediately. When this function is activated, the sanitation data and start time is configurable.
[Operation Instructions]
(1) At the
FUNCTION
page, locate “
Disinfection
”, and then access to the
DISINFECTION
setting page by
pressing the OK key
.
(2) At the
DISINFECTION
setting page, select “
Set clock
”, “
Set week
” or “
Set temp
” through the Left/Right
key
and then modify the corresponding setting through the Up/Down key
.
(3) When the mode setting is finished, then by pressing “
Save
”, a pop-up window will pop up to remind if you
are determined to save this setting. If so, press the OK key
. If not, press the Cancel key
to not
save this setting.
(4) When the setting is saved, the control then will back to the
FUNCTION
page and the cursor will be where
the “
Disinfection
” is, which indicates this setitng for timed disinfection successes.
[Notes]
(a) It can be activated only when the “Water tank” is set to “With”.
(b) It can be set to “On” or “Off” no matter if the unit is in operation or not
(c) When "Disinfection" has been activated, the unit will perform disinfection at the set time once each week.
(d) When “Disinfection” is set to “On”, if you intend to set the “Emergen. mode”, “Holiday mode”, “Floor Debug”,