16
Swimming pool-leaving water temp
T-Swimming out
17
Discharge pressure
Dis.pressure
18
Enthalpy-enhancing pressure
En.pressure
19
Suction pressure
Su.pressure
20
Target temperature for Weather-dependent Mode
T-auto mode
21
Target temperature for floor debug
T-floor debug
22
Time period for floor debug
Debug time
2.4.3 Error View
At the error view pages, the user is enabled to see which error the unit suffers.
[Operation Instructions]
(1) At the
VIEW
page, select
Error
and then press the OK key
to go to the
ERROR
page.
(2) At the
Error View
page, it is able to view each error.
[Notes]
(a) The real-time error will show on the control. Taking Error 2 in the above figure for example, when it is
recovered, it will disappear and be replaced by Error 3, and other errors follow the same way.
(b) If the total no. of errors exceed six, other errors should be viewed by switching pages through “
Last
”
and “
Next
”
.
(c) Any one among “
IDU auxiliary heater 1 error
”, “
IDU auxiliary heater 2 error
”, “
Water tank
heater error
”
occurs, the control will beep until this error has been cleared.
(d) See the following table for error description.
No.
Full Name
Displayed Name
Error Code
1
Ambient temperature sensor error
Ambient sensor
F4
2
Defrost temperature sensor error
Defro. sensor
d6
3
Discharge temperature sensor error
Disch. sensor
F7
4
Suction temperature sensor error
Suction sensor
F5
5
Outdoor fan error
Outdoor fan
EF
6
Compressor internal overload protection
Comp. overload
H3
7
High pressure protection
High pressure
E1
8
Low pressure protection
Low pressure
E3
9
High discharge protection
Hi-discharge
E4
10
Refrigerant loss protection
Refri-loss
P2
11
Heat pump-water pump protection
HP-pump
E0
12
Solar kit-water pump protection
SL-pump
EL