22
5
Tank temperature
T-water tank
40~80°C
104~176°F
50°C/122°F
6
Eheater-on ambient
temperature
T-Eheater
-20~18°C
-4~64°F
-7°C/19°F
7
Extra-heater-
on ambient
temperature
T-Extraheater
-20~18°C
-4~64°F
-15°C/5°F
8
Max heat
pump waterout
temperature (no
eheater)
T-HP Max
40~50°C
104~122°F
50°C/122°F
9
Solar kit-max water
temp
Solarwater
Max
50~80°C
122~176°F
80°C/176°F
10
Lower limit ambient
temperature at the
Weather-dependent
Mode for heating
Lower AT-Heat
-20~5°C
-4~41°F
-15°C/5°F
Once setting of the
"Weather-depedent
mode" changes, it will
back to the default value.
11
Upper limit
temperature at the
Weather-dependent
Mode for heating
Upper AT-Heat
10~35°C
50~95°F
15°C/59°F
Once setting of the
"Weather-depedent
mode" changes, it will
back to the default value.
12
Upper limit room
temperature at the
Weather-dependent
Mode for heating
Upper RT-Heat
22~30°C
72~86°F
24°C/75°F
Once setting of the
"Weather-depedent
mode" changes, it will
back to the default value.
13
Lower limit room
temperature at the
Weather-dependent
Mode for heating
Lower RT-Heat
18~21°C
64~70°F
18°C/68°F
Once setting of the
"Weather-depedent
mode" changes, it will
back to the default value.
14
Upper limit water-out
temperature at the
Weather-dependent
Mode for heating
Upper WT-
Heat
46~60°C[High
temp.]
30~45°C[Normal
temp.]
115~140°F[High
temp.]
86~113°F
[Normal temp.]
55°C/131°F[High temp.]
35°C/95°F[Normal
temp.]
Once setting of the
"Weather-depedent
mode" changes, it will
back to the default value.
15
Lower limit water-out
temperature at the
Weather-dependent
Mode for heating
Lower WT-
Heat
36~45°C[High
temp.]
25~29°C[Normal
temp.]
97~113°F[High
temp.]
77~84°F
[Normal temp.]
40°C/104°F[High temp.]
25°C/77°F[Normal
temp.]
Once setting of the
"Weather-depedent
mode" changes, it will
back to the default value.
16
Lower limit ambient
temperature at the
Weather-dependent
Mode for cooling
Lower AT-Cool
10~25°C
50~77°F
25°C/77°F
17
Upper limit
temperature at the
Weather-dependent
Mode for cooling
Upper AT-Cool
26~48°C
79~118°F
40°C/104°F