2.2.15 Solar Kit
When the solar system is prepared, this function will decide which period to let the solar system to run. However,
if the solar system will run virtually depends on the temperature difference between the solar panel and the water
tank.
[Operation Instructions]
(1) Go to the FUNCTION page and locate “timer”, then press OK key
to go to the page as shown below.
No.
Full Name
Displayed Name
Range
Default
1
Solar kit start time
Start time
0:00~23:59
8:00
2
Solar kit stop time
Stop time
0:00~23:59
18:00
(2) At the “
Solar Timer
” page, locate “
Start time
” or “
End time
” through the up and down keys
and
then adjust the start or stop time also through the up and down keys
.
(3) After configuration, press “Save” and then a dialog box will pop up. In the dialog box, press “OK”
to
confirm the configuration, or press “Cancel”
to cancel this configuration.
(4) After saving the configuration, this page will automatically back to the
FUNCTION
page with the cursor
stayed at “
Solar timer
”, and then through the up and down keys
to set it to be “ON” to activate
“
Solar timer
”.
[Notes]
(a) Once “
Solar timer
” is activated,it cannot be deactivated through ON/OFF operation but be done manually.
(b) “
Start time
” and “
End time
” will be memorized upon power failure
(c) It can be set under both ON and OFF states.
(d) When "Solar kit" is set to "Without", this function will be forced to be deactivated and configurable.
2.2.16 Floor Debug
This function will make the unit to perform periodic preheating to the floor for the initial run once floor coils have
been installed.
[Operation Instructions]
(1) At the homepage, by pressing the Function key
access to the
FUNCTION
page, and then locate
where “
Floor debug
” is, after that, press OK key
to go to the
FLOOR DEBUG
setting page.