5
Function Settings
No.
Full Name
Displayed Name
Range
Default
Remarks
1
Running mode
setting
Mode
Cool
Heat
Hot water
Cool+Hot water
Heat+Hot water
Heat
1. When the water tank is
unavailable, then only “Cool”
and “Heat” are included in the
range.
2. For the heating only unit, only
"Heating" mode is available.
2
Control state
Ctrl. state
T-water out /
T-room
T-water
out
“T-Room” is available only
when “Remote Sensor” is set to
“With”.
3
Fast hot water
Fast hot water
On/Off
Off
When the water tank is
unavailable, this function will
be reserved, and the LCD will
display ‘Reserved’.
4
Water out
temperature
control
T-water ctrl.
High temp.
/Normal temp.
Normal
temp.
This setting depends on the
"Floor config".
When the "Floor config" is set to
"With", the setting is defaulted
to be "Normal temp." and can
not be changed by the user.
When the "Floor config" is set
to "Without", this setting can be
changed freely.
5
Cool+hot water
Cool+hot water
Cool/Hot water
Cool
When the water tank is
unavailable, this function will
be reserved, and the LCD will
display ‘Reserved’.
6
Heat+hot water
Heat+hot water
Heat/Hot water
Heat
When the water tank is
unavailable, this function will
be reserved, and the LCD will
display ‘Reserved’.
7
Quiet mode
Quiet mode
On/Off
Off
/
8
Quiet timer
Quiet timer
On/Off
Off
/
9
Weather-
dependent mode
Weatherdepend
On/Off
Off
/
10
Holiday release
Holiday release
On/Off
Off
/
11
Disinfection
Disinfection
On/Off
Off
When the water tank is
unavailable, this function will
be reserved, and the LCD will
display ‘Reserved’.
1. The disinfection date ranges
from Mondry to Sunday.
Saturday is defaulted.
2. The disinfection time ranges
from 00:00~23:00. 23:00 is
defaulted.
12
Weekly timer
Weekly timer
On/Off
Off
/
13
Clock timer
Clock timer
On/Off
Off
/
14
Temperature
timer
Temp. timer
On/Off
Off
/