Chapter 3. Auto-Programming
3-4
NAC, Relay, and Signal Circuit Output Mode
Assignments
Table 3-3 lists the default output mode (steady, temporal,
etc.) assignments for the NAC, Relay, and Signal circuits.
The output mode is a programmable attribute and it can be
manually changed, as described in Chapter 5 of this manual.
Annunciator Defaults
Annunciator cards found during the Auto-Program process
are added into the default configuration.
•
LCD Annunciators are configured to receive all events.
Refer to Chapter 6 for information on manually pro-
gramming which events are received by the LCD
Annunciator.
•
LED Annunciators and 24-I/O modules are not pro-
grammed for default operation.
DACT Defaults
The defaults for the DACT are listed below. Refer to Chap-
ter 5for information on manually programming the DACT.
•
Tone else pulse dialing
•
AC Fail reporting delay is 6 hours
•
Reporting format is CID
•
Primary and Secondary Phone Number. There are no
values for the primary and secondary phone numbers or
account codes.
•
The CID Group and CID Point Identifier default to the
IDNet device address.
•
Default event codes are shown in Table 3-4.
*Any other trouble not specifically mentioned would have a code of 330.
For example, a trouble on an output device would report an event code of 330.
SIGNAL
OTS
General Alarm Signal (on-til-silence)
ISOL
ISOL
IDNet loop isolator
SIG1-2
OTS
General Alarm Signal (on-til-silence)
SIG3-4
OTR
General Alarm Signal (on-til-reset)
AUX1
OTR
General Alarm Relay (on-til-reset)
AUX2
TRBL
Trouble Relay (on-til-clear)
Table 3-3 Default NAC, Relay, Signal Circuit Output
Mode Assignments
Circuit
Default Output Method
SIG1-2 (NAC)
Temporal Code A three pulse coding pattern
consisting of three ½ second pulses, each sep-
arated by ½ second silence. Each group of
three pulses is separated by 1.5 seconds of
silence.
SIG3-4 (NAC
Synchronized. Used with visual NACs. Pro-
grams all visuals to flash simultaneously.
AUX1 & AUX2
Steady on
RELAY Modules
Steady on
SIGNAL Mod-
ules
Steady on
Table 3-2 Default Function Type Assignments,
IDNet Devices, NACs, and Relays (Cont’d)
Device
Function
Type
Description
Table 3-4 Default CID Event Codes
Function Type
Fire
Supervisory
Trouble
FIRE
110
-
330
WATER
113
-
330
HEAT
114
-
330
DUCT
116
-
330
PULL
115
-
330
SMOKE
111
-
330
SO
-
200
330
WSO
110
200
330
SUPV
-
200
330
UTIL
-
-
330
TROUBLE
-
-
330
VSMOKE
111
-
330
LATSUPV
-
200
330
STYLEC
110
-
330
OTHER TRBL*
-
-
330
Technical Manuals Online! - http://www.tech-man.com
firealarmresources.com
Summary of Contents for TrueAlarm 4008- 9121
Page 1: ...Technical Manuals Online http www tech man com firealarmresources com...
Page 6: ...Technical Manuals Online http www tech man com firealarmresources com...
Page 10: ...Technical Manuals Online http www tech man com firealarmresources com...
Page 34: ...Technical Manuals Online http www tech man com firealarmresources com...
Page 58: ...Technical Manuals Online http www tech man com firealarmresources com...
Page 68: ...Technical Manuals Online http www tech man com firealarmresources com...
Page 72: ...Technical Manuals Online http www tech man com firealarmresources com...
Page 80: ...Technical Manuals Online http www tech man com firealarmresources com...
Page 85: ...Technical Manuals Online http www tech man com firealarmresources com...
Page 86: ...Technical Manuals Online http www tech man com firealarmresources com...