
User Manual For - CONTROLLER/DATA RECORDER MultiCon CMC-N16
temperatures in the hall of the symbols A1, A2, A3, A4, and the temperature alarm condition.
To do this:
a) For the temperature reading of sensor 1 with the symbol A1:
–
touch the screen and press the
Menu
button,
–
press the
Device configuration
button,
–
enter the
Logical channels
menu,
–
using the arrows in the top navigation bar, select any
logical channel
(such as 1),
–
in the
Name
parameter write
Temperature A1
,
–
Mode
parameter set as
Hardware input
,
–
Source parameter set as
Inp. A1: Universal
–
press the
Source configuration
button to set the source configuration options,
•
Mode
parameter set as
Thermocouple K
,
•
in
Low Limit
parameter write
-200°C
,
•
in
High Limit
parameter write
1370°C
,
–
for
Display
block parameters:
125