External Connections
Manufacturers Instructions must be referred to when
installing boiler condensate discharge pipes
Figure 7 –
Example of a purpose made soakaway
Key
1
Condensate discharge pipe from boiler
2
Ground (this section of the condensate discharge pipe may be run either above or below
round level); End cut at 45°
3
Diameter 100 mm minimum plastic tube
4
Bottom of tube sealed
5
Limestone chippings
6
Two rows of three 12 mm holes at 25 mm centres, 50 mm from bottom of tube and facing
away from house
7
Hole depth 400 mm minimum by 300 mm diameter
8
Minimum internal diameter 19 mm
9
Pipe size transition point
10
Minimum internal diameter 30 mm
11
Water/weather proof insulation
1
2
10
5
9
4
8
3
7
6
11