FOR THE INSTALLER
COMMISSIONING
Run the following checks before turning on the boiler for the first time:
– Check that there are no flammable fluids or materials in the vicinity of the boiler.
– Make sure that the electrical connection has been completed properly and the earth wire is connected to an
effective grounding plant.
– Open the gas valve and check that the fittings are tight, including the burner fitting.
– Make sure that the boiler is properly configured for the gas supply.
– Check that the combustion exhaust duct is clear and properly installed.
– Make sure that all shutters are open.
– Make sure that the system is filled with water and properly vented.
– Check that the circulator pump is running properly
– Vent all air from the gas line with the pressure fitting cock on the gas valve intake.
- Ensure that the checklist is compiled after commissioning.
Fonderie Sime S.p.A. declines all liability due to errors in printing or transcription, and reserves the right to modify its
technical and sales materials without notification.
COMPLIANCE
Our company declares that the MURELLE 110 BOX ErP boilers conform to the essential requirements of the following directives:
- Boiler Efficiency Directive 92/42/EEC
- Gas Appliances Regulations 2016/426/EC
- Electromagnetic Compatibility Directive 2014/30/EU
- Low Voltage Directive 2014/35/EU
- Ecodesign Directive 2009/125/EC
- Regulation (EU) N. 813/2013 - 811/2013
CONTENTS
2 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3 CHARACTERISTICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4
Important Information
IT IS A STATUTORY REQUIREMENT THAT ALL GAS APPLIANCES BE INSTALLED BY COMPETENT PERSONS,
IN ACCORDANCE WITH THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS (CURRENT EDITION).
The manufacturer’s instructions must not be taken as overriding any statutory requirements, and failure to
comply with these regulations may lead to prosecution.
No modifications to the appliance should be made unless they are fully approved by the manufacturer.
GAS LEAKS:
DO NOT OPERATE ANY ELECTRICAL SWITCHES, OR USE OPEN FLAMES. TURN OFF THE GAS SUPPLY
AND VENTILATE THE AREA BY OPENING DOORS AND WINDOWS Contact the gas emergency service on 0800111999.
VERY IMPORTANT!
PLEASE MAKE SURE YOUR COMMISSIONING CHECKLIST AND THE SERVICE INTERVAL RECORDS ENCLOSED
ARE FILLED IN CORRECTLY.
ALL GAS SAFE REGISTERED INSTALLERS CARRY A GAS SAFE ID CARD.
BOTH SHOULD BE RECORDED IN YOUR COMMISSIONING CHECKLIST AND A SERVICE INTERVAL RECORDS.
YOU CAN CHECK YOUR INSTALLER IS GAS SAFE REGISTERED
BY CALLING ON 0800 408 5500 OR ALTERNATIVELY WWW.GASSAFEREGISTER.CO.UK