21
Neutro-Vac
5200470 Rev B
DC66, DC75, DC84, and DC90 Bag Style Collectors (see Figure 13)
Figure 13: Dust Collector (Bag Style)
Filter Cleaning
Cabinet collectors are off line cleaners. Cleaning cannot take place until 60 seconds
after the blower is turned off.
NOTE
– Attempting to clean the filter while the collector is operating will
cause the dust to penetrate the filter media and shorten filter life.
WARNING
– Filter cleaning exposes operator to collector contaminant.
Wear safety goggles and dust respiring-breathing apparatus.
Filters are chemically treated for fire resistance. They will not ignite unless exposed
to a continuous flame. You should not however, attempt to collect materials such
as lint and grinding dust in the same collector.
WARNING
– To avoid a potential fire hazard caused by sparks in the dust
collector, do not mix combustible materials such as buffing line, paper,
wood, dust, aluminum and magnesium with dust generated from grinding
ferrous metals.
Under no condition should machine operator put a lit cigarette or any burning
object into the hood or ducting of the dust control system.
The filters in the bag type dust collector are semi-permanent and will provide long,
efficient service when routine maintenance is performed.