22
Neutro-Vac
5200470 Rev B
1. Shake the filters to remove any clinging material daily. To perform this
operation, push down vigorously on the filter shaker lever located on the side of
the cabinet. On the hopper model, pull handle firmly.
2. Hand brushing may be required if the collected material sticks to the filters.
Care must be taken to prevent the tearing or puncturing of the filter cloth. If
the filters become saturated with oil, they must be dry cleaned.
3. Replace filters every two years when used under normal operating conditions.
Filters should not be removed except for dry cleaning or replacement. When
ordering replacement filters, be sure to include the model and serial number of
your dust collector.
Filter Replacement
1. Disconnect electrical power.
2. Remove upper and lower doors.
3. Remove and discard set screws and hold down channels.
4. Remove old bags.
5. Clean bottom of cabinet ledge with stiff brush.
6. Remove and empty dustpan.
7. Remove banded replacement filter from box.
NOTE
– DO NOT remove bands from filter.
8. Fully loosen wing screws.
9. Move slide latches to the rear, away from gasket.
10. Insert banded replacement filter over shaker bar.
11. Rest banded replacement filter on shaker bar.
12. Cut and remove bands.
13. Remove cardboard protectors.
14. Insert one hand midway under each side of the filter.
15. Push the filter to bottom of cabinet filter frame.
16. Place one hand in the center of filter.
17. Hold filter against bottom of cabinet ledge.
18. Push each slide latch over cabinet ledge. DO NOT tighten wing screws.
19. Adjust filter for good fit.
20. Finger tighten wing screws.
21. Remove support bar from box.
22. Place support bar over center of filter.
23. Insert small wing screw through holes in support bar.
24. Hand tighten all wing screws.