20
Neutro-Vac
5200470 Rev B
3. Reinstall screen by butting it up against the upper end cap of filter. Stretch
screen tight before sealing Velcro® edges. The screen must not extend below the
lower edge of the filter.
Filter Replacement
Filter replacement exposes operator to collector contaminant. Wear safety goggles
and dust respiring-breathing apparatus.
1. Disconnect electrical power.
2. Loosen knobs on bottom door and remove door (knobs remain attached to the
door).
3. Loosen the four knobs supporting the filter.
4. Rotate retaining ring counter clockwise to release ring and filter.
WARNING
– Filter may be heavy due to accumulation of dust. Be careful
the filter doesn’t drop when the ring is rotated.
5. Remove the support ring from filter.
6. Check gasket surface on shaker panel for dust. Clean if necessary.
7. Install supplied screen on replacement filter.
8. Install new filter on shaker panel, reusing the filter support ring.
9. Tighten the filter support ring by hand.
10. To insure an airtight seal, inspect the door gasket on the cabinet. Repair or
replace if necessary.
11. Reinstall door and tighten knobs securely by hand.
12. Connect electrical power and resume operation.
NOTE
– A slight bleed-through on any new filter is normal and will
quickly disappear as the filter seasons. If bleed through persists, contact
your Simco-Ion representative.