8
Neutro-Vac
5200470 Rev B
Ductwork Installation for All Units
CAUTION
– Do not attempt to change the number or size of inlets. If the
dust collector is operated with more than the maximum permissible inlet
area, the motor and filters may become overloaded.
NOTE
– When installing ductwork, use the shortest possible runs. Long
radius elbows and at least 45-degree branches. Avoid the use of airflow tees.
Ductwork should be of a proper size to permit passage of the air velocities
recommended for the material being collected. A complete selection of galvanized
steel pipe elbows, branches and fittings are available from Simco-Ion. Stainless steel
components are also available upon special order. If you require any assistance in
the design or selection of ductwork, contact your local Simco-Ion representative.
1. Connect piping joints with sheet metal screws, rivets or solder.
2. Wrap each joint with a single layer of duct tape. This will insure a rigid, airtight
system.
Power Supply for IQ Easy Static Bars
IQ Easy static bars are equipped with an integrated high-voltage power unit, ion
emitters and status LEDs. They require a 24 VDC supply voltage to be provided
via a 5-pin M12 connector. For detailed instructions, see the publication included
with the static bars.
Power Supply for MEB Static Bars
The following are brief instructions for power supplies used with the MEB static
bars. For detailed instructions, see the publication included with the power supplies.
1. Locate power supply where high voltage cable(s) from the static bar will reach.
2. Locate power supply where it is accessible but out of the way.
3. Do not cut high voltage cable(s) until everything has been mounted.
4. Orient / turn power unit so HV connection ports are facing downward.
The power supply is designed for flat surface mounting. It can easily be mounted
using flanges at the base of the unit. Proper grounding of the power supply is
essential for safe and efficient operation.
CAUTION – Electrical Shock Hazard
Failure to properly ground the power supply may result in an electrical
shock hazard to personnel and inefficient operation of the equipment. Do
not apply line power until all grounds and high voltage connections have
been completed.
Grounding the Power Supply for MEB Static Bars
There are three ways to ground the power supply: