90
007-4644-001
A: Specifications and Requirements
Environmental
Table A-3 list the environmental requirements for the TP9300.
Caution:
If you receive the rack and enclosures in cold weather (below 32
º
F (0
º
C
))
, leave
them crated for at least 24 hours to prevent condensation. This 24-hour stabilization
period can be modified either up or down, depending on the outside temperature at
arrival.
Table A-3
Environmental Requirements
Environment
Unit of Measure
Requirement
Air flow
N/A
Air flow is from front to rear
Temperature
Operating range
Storage range
Transit range
10
º
C to 35
º
C (50
º
F to 10
º
F)
-10
º
C to 50
º
C (14
º
F to 122
º
F)
-40
º
C to 60
º
C (-40
º
F to 140
º
F)
Temperature change
(maximum allowed)
Operating
Storage
Transit
10
º
C per hour (21
º
F per hour)
15
º
C per hour (31
º
F per hour)
20
º
C per hour (42
º
F per hour)
Relative humidity
(no condensation)
Operating range
Storage range
Transit range
Max. dew point
Max. humidity gradient
20% to 80%
10% to 90%
5% to 95%
28
º
C (82
º
F)
10% per hour
Noise level
Steady
Non-steady
Normal operation
6.8 bels (maximum)
6.8 bels (maximum)
65 dBA
Altitude
Below Sea Level
Above Sea Level
Operating range
Storage range
Transit range
Operating range
Storage range
Transit range
30.5 m (100 ft)
30.5 m (100 ft)
30.5 m (100 ft)
3,000 m (9,840 ft)
3,000 m (9,840 ft)
12,000 m (40,000 ft)
!
Summary of Contents for Total Performance 9300
Page 1: ...SGI Total Performance 9300 RAID User s Guide 007 4644 001 ...
Page 3: ...007 4644 001 iii Record of Revision Version Description 001 May 2003 Original publication ...
Page 4: ......
Page 8: ......
Page 12: ......
Page 44: ......
Page 62: ......
Page 96: ......
Page 114: ......
Page 120: ......