Checking the Indicator Lights
007-4644-001
39
ID conflict indicator
Amber
Off
On,
steady
Enclosure number is set incorrectly;
enclosure number is in use by another
subsystem on the loop.
Fan canister
Fan fault indicator
Amber
Off
On,
steady
Fan canister failure; overtemp condition.
Power supply
canister
Power supply fault
indicator
Amber
Off
On,
steady
Power supply failure; overtemp condition.
Power supply power
indicator
Green
On, steady
Off
Power supply off; power supply
disconnected; power supply is seated
incorrectly; no power to drive enclosure; no
power to storage array.
a. Always use the storage management software (TPSSM) to precisely identify a failure.
b. If nothing is connected to the corresponding connector, this fault light is on. If a cable is connected and it is functioning properly, this light is
off.
c. This indicates a problem only if an SFP is plugged into the corresponding connector (see footnote a). Also, more than one bypass indicator
will be on if the connection fails. Usually, if an SFP fails, its bypass indicator will come on, as will the bypass indicator of the module to which
it is connected.
d. The overtemp indicator comes on if the internal drive enclosure temperature reaches 40
º
C (104
º
F). See “Troubleshooting an Overtemp
Condition” in this chapter for more information.
Table 3-2
Storage Enclosure Rear Indicator Lights
(continued)
Component
Indicator Light
Color
Normal Operation
Problem
Indicator
Condition Indicated
a
Summary of Contents for Total Performance 9300
Page 1: ...SGI Total Performance 9300 RAID User s Guide 007 4644 001 ...
Page 3: ...007 4644 001 iii Record of Revision Version Description 001 May 2003 Original publication ...
Page 4: ......
Page 8: ......
Page 12: ......
Page 44: ......
Page 62: ......
Page 96: ......
Page 114: ......
Page 120: ......