Replacing a Failed Power Supply Module
007-4644-001
51
Figure 4-4
Removing and Installing a Power Supply Module
Danger:
Shock can occur. Make sure the power supply is turned off and
unplugged before you remove or install it.
10. Make sure that the power switch on the new power supply module is turned off.
11. Wearing antistatic protection, slide the new power supply module into the slot.
12. Close the lever and lock it into place.
13. Secure the power cord in the power cord clip.
14. Plug in the power cord and turn on the power switch.
15. Check that the power indicator on the new canister is on and that the fault indicator
is off (see Figure 4-4).
•
If the power indicator is off, the canister might be installed incorrectly. Remove
it and reinstall it.
•
If the fault indicator is on, or the power indicator stays off, use TPSSM to
determine the problem.
Locking lever
Power supply