Programming
151059
5-25
5.4.4.3 How to Configure Output for Bad Data Blocks
This feature selects how bad data blocks will be sent from the receiver to the automation
computer. If Strip Bad is selected then an indicator will be sent to the automation computer
when a bad data block is received, but the actual bad data block will not be sent. If Send Bad
is selected an indicator will be sent to the automation computer along with the bad data block.
1. Enter program mode. (See Section 5.1.)
2. Press
for General Options.
3. Press
for System Options.
4. Press
until display will flashes on the Bad Data Blocks:
Strip_Bad
5. Press
or
until the display flashes on the desired setting.
6. Press
.
To Exit press
until you return to the main menu.
5.4.4.4 How to Set the Normal State of the Auxiliary Relay Contact
The auxiliary relay contact is a Form C relay. This feature allows you to set the state of the
auxiliary relay normally open contact when power is applied to the receiver.
1. Enter program mode. (See Section 5.1.)
2. Press
for General Options.
3. Press
for System Options.
4. Press
until display will flash on the auxiliary relay setting:
Aux Relay=
Off
5. Press
or
until the display flashes on the desired setting.
6. Press
. To Exit press
until you return to the main menu.