Instruction Manual StackGuard
36
10266E/1
5.4
Replacing the desiccant
Action
1.
Disconnect the voltage supply to the SIREL.
2.
Loosen the three screws (arrows) and remove
the housing.
3.
Remove the saturated desiccant sachet
(location A) from its holder by carefully
working it out.
4.
Roll the new desiccant sachet together and
insert it carefully into the holder.
5.
Replace the housing and fasten it with the
three screws.
6.
Reconnect the voltage supply to the SIREL.