Instruction Manual StackGuard
10266E/1
13
Action Remarks
4.
Fix the 450 mm long hose section (7) to
the cooling section inlet (6).
This hose section will be connected to
the purge air blower later!
→
3.5
Installation of the purge air blower and coarse
filter
Pos. Name
1 Connection
hose
(450 mm) between
cooling section inlet and
purge air blower
2
Purge air blower
3 Connection
hose
between purge air
blower and coarse filter
4
Coarse filter for purge
air blower
Figure 11: Purge air blower and coarse filter installation
Action Remarks
1.
Place the purge air blower (2) on the ground or
on a firm surface.
→
2.
Fix the coarse filter (4) to the desired position.
→
3.
Connect the coarse filter outlet with the air
intake supports of the purge air blower to the
connection hose section (3)
→
4.
Fix the hose (450 mm long) coming from the
cooling section inlet onto the purge air blower
inlet.
→