![Siemens TM Timer DIDQ Commissioning Manual Download Page 51](http://html.mh-extra.com/html/siemens/tm-timer-didq/tm-timer-didq_commissioning-manual_1265510051.webp)
3.3.4.3
Configuring I/O channels
Procedure
To configure I/O channels as measuring input input (Timer DI) and output cam (Timer DQ) in
the TM Timer DIDQ 16x24V technology module,
proceed as follows.
1. The technology module is selected in the device view. To configure the I/O channels, click
on channel parameters in the "General" tab in the inspection window.
2. In the example, select the value "Use input/output individually" for the DQ0 / DI1 channel
group from the "Configuration DQ/DI group" drop-down list. This allows the channels DQ0
and DI1 to be parameterized and used independently of one another.
Figure 3-21 Channel parameter - configuration DQ/DI group
3. Save and compile the project.
4. To interconnect the channels with the technology objects outputCam or measuringInput,
open the SIMOTION configuration.
Note
This setting allows channel DQ0 to be interconnected as output cam and DI1 as measuring
input under SIMOTION SCOUT TIA.
Configuring
3.3 SIMOTION SCOUT TIA
Technology Modules TM Timer DIDQ for SIMOTION SCOUT and SIMOTION SCOUT TIA
Commissioning Manual, 01/2015
51