Page EN-18
SITRANS LR560 (FF)
7ML19985XR82
mmmmm
English
Maintenance
SITRANS LR560 requires no maintenance or cleaning under normal operating conditions. If
cleaning becomes necessary:
1)
Note the antenna material and the process medium, and select a cleaning solution that
will not react adversely with either.
2)
Remove the device from service and wipe the antenna clean using a cloth and suitable
cleaning solution.
Unit Repair and Excluded Liability
For detailed information, please see the inside back cover.
Temperature De-Rating Curve
Wiring setups for hazardous area installations
The following wiring options are available for hazardous area installations:
•
Non-Sparking/Energy Limited wiring (Europe) and Dust Ignition Proof wiring (Europe/
International)
on page 20
•
Non-incendive and Dust Ignition Proof wiring (US/Canada)
on page 21
In all cases, check the device label on your instrument, and confirm the approval rating.
WARNING:
Never attempt to loosen, remove or disassemble process
connection or instrument housing while vessel contents are under pressure.
Process Temperature (°C)
Ambi
en
t T
emp
er
atur
e (
°C
)
high
temperature
version
standard
version