Page EN-16
SITRANS LR260 (HART) – QUICK START MANUAL
A5E32106122
mmmmm
English
1.3. Sensor Units
Selects the units for the Quick Start variables (high and
low calibration point, and level, distance, or space).
1.4. Operation
1.5. Low Calibration Point
Distance from Sensor Reference to Low Calibration Point: usually process empty level. See
Operation (1.4.) for an illustration.
1.6. High Calibration Point
Distance from Sensor Reference to High Calibration Point: usually process full level. See
Operation (1.4.) for an illustration.
Operation
types
NO
SERVICE
The SITRANS LR260 stops updating measurements and associ-
ated loop current. Last valid measurement is displayed.
LEVEL
Distance to material surface referenced from Low Calibration
Point (process empty level).
SPACE
Distance to material surface referenced from High Calibration
Point (process full level).
DISTANCE
Distance to material surface referenced from Sensor Reference
Point.
Default: Distance
Values
Range: 0.0000 to 30.000 m
Values
Range: 0.0000 to 30.000 m
Options
M, CM, MM, FT, IN
Default: M
high cal.
point
low cal.point
level
space
distance
sensor reference point
Summary of Contents for SITRANS LR260
Page 1: ...SITRANS Radar Transmitters SITRANS L 260 HART R Quick Start Manual 12 2013 ...
Page 2: ......
Page 22: ...Page EN 20 SITRANS LR260 HART QUICK START MANUAL A5E32106122 mmmmm English Notes ...
Page 42: ...Side DA 20 SITRANS LR260 HART KVIKSTART MANUAL A5E32106122 mmmmm Dansk Notater ...
Page 62: ...Seite DE 20 SITRANS LR260 HART KURZANLEITUNG A5E32106122 mmmmm Deutsch Notizen ...
Page 102: ...Página ES 20 SITRANS LR260 HART PUESTA EN MARCHA RÁPIDA A5E32106122 mmmmm Español Notas ...
Page 122: ...Page FR 20 SITRANS LR260 HART MISE EN SERVICE RAPIDE A5E32106122 mmmmm Français Notes ...
Page 202: ...Sivu FI 20 SITRANS LR260 HART PIKAKÄYTTÖOPAS A5E32106122 mmmmm Suomi Huomautukset ...
Page 222: ...Sida SV 20 SITRANS LR260 HART SNABBSTARTSMANUAL A5E32106122 mmmmm Svenska Anmärkningar ...