Installation
3-14
SITRANS FM Intermag 2 Flow Transmitter
Operating Manual - A5E00102775-03
Attention!
The sensors have the same terminal names, the lines must be
connected 1:1.
Terminals 55 and 66 are not used.
With sensors with IP68 degree of protection, the cable colors or the
identification tag on the sensor cables must be observed
.
Table 3.1 Sensor terminal assignment
Terminal
Designation
Cable color
for sensors
with IP68 degree
of protection
5
magnetic field current 1
brown
magnetic
top
6
magnetic field current 2
white
magnetic
field
current
p
terminal
block
7
potential equalization
green-yellow
current
cable
b oc
29
SmartPLUG-supply (-5 V)
green
1)
22
Measuring ground
red
bottom
23
electrode 1
brown
electrode
cable
terminal
block
24
electrode 2
white
cable
b oc
30
SmartPLUG-supply (+5 V)
blue
1)
1)
only for sensors with SmartPLUG
You must use a line with a cross section of 3 x 1.0 mm
2
to wire the
magnetic current line and a line with a cross section of 5 x 0.5 mm
2
to
wire the electrode line (including the supply voltage of the SmartPLUG)
both of which are shielded (e.g. LIYCY).
Prepare the cable before connection as shown in Figure 3-15.
10...12
mm
5...10
mm
75...80
mm
Braided screen
Connector sleeve
Figure 3-15 Preparation of the electrode and magnetic field current cable
Summary of Contents for SITRANS F M Intermag 2
Page 2: ......
Page 8: ...SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 I 4 ...
Page 111: ...Appendix 7 3 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Page 113: ...Appendix 7 5 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Page 114: ...Appendix 7 6 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Page 115: ...Appendix 7 7 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Page 116: ...Appendix 7 8 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Page 117: ...Appendix 7 9 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Page 118: ...Appendix 7 10 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Page 119: ...Appendix 7 11 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Page 120: ...Appendix 7 12 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Page 128: ...Appendix 7 20 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Page 129: ...Appendix 7 21 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...