Operation
5-27
SITRANS FM Intermag 2 Flow Transmitter
Operating Manual - A5E00102775-03
S
Hysteresis
, menu item
3.1.3.3
The limit values (menu items
3.1.3.1
and
3.1.3.2
) can have a
hysteresis added to prevent ”fluttering” of the switching output
(see Figure 5-9).
S
Density
, menu item
3.1.4
You must specify unit and density here. The volume flow q
v
is
converted to mass flow q
m
automatically using the
formula (q
m
= q
v
*
r
).
Measured variable
limit
max.
time
hysteresis
Measured variable
limit
min.
time
hysteresis
limit alarm
limit alarm
Figure 5-9 Limit value message and hysteresis
S
Direction
, menu item
3.1.5.
This item is divided into:
-
Flow direction
, menu item
3.1.5.1
The flow direction is preset at the factory and indicated by the
arrow on the sensor. If the flow direction does not match the
direction of the arrow it must be adapted in this menu item.
Signal
Analog
output
Pulse/Freq.
output
Signal
Analog
output
Pulse/Freq.
output
Measuring direction or flow direction
reverse
forwards
Measuring direction or flow direction
reverse
forwards
Figure 5-10 Setting
forw.+rev.
Figure 5-11
Setting
forwards
Summary of Contents for SITRANS F M Intermag 2
Page 2: ......
Page 8: ...SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 I 4 ...
Page 111: ...Appendix 7 3 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Page 113: ...Appendix 7 5 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Page 114: ...Appendix 7 6 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Page 115: ...Appendix 7 7 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Page 116: ...Appendix 7 8 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Page 117: ...Appendix 7 9 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Page 118: ...Appendix 7 10 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Page 119: ...Appendix 7 11 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Page 120: ...Appendix 7 12 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Page 128: ...Appendix 7 20 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...
Page 129: ...Appendix 7 21 SITRANS FM Intermag 2 Flow Transmitter Operating Manual A5E00102775 03 ...