11.6 Calculating the permissible switching frequency
SIRIUS 3RW30 / 3RW40
Manual, 01/2010, 535 1995-02 DS01
85
Calculating the number of starts / hour of a 3RW40 for side-by-side assembly and vertical
mounting
Assembly of a 3RV2021 motor starter protector and connection of a 3RW40 24 soft starter
with cables and vertical mounting for CLASS 10 starting:
Result
The pump could be started five times an hour providing the above assembly conditions are
complied with (side-by-side assembly, vertical mounting). A switching frequency of up to 80
starts per hour can be achieved by equipping the 3RW4026 with the optional 3RW4928-
8VB00 fan.
5 9
5 :
5 9
5 :
5 9
5 :
6WDQGDORQH
DVVHPEO\
6WDQGDORQH
DVVHPEO\
$VVHPEO\W\SH
*UDSK
9HUWLFDOPRXQWLQJ
6LGHE\VLGH
DVVHPEO\
6LGHE\VLGH
DVVHPEO\
3RZHUHOHFWURQLFV
7\SH
ವ$FFRUGLQJWR,(&DQG8/&6$
IRUVWDQGDORQHDVVHPEO\$&D
/RDGUDWLQJZLWKUDWHGRSHUDWLRQDOFXUUHQW,
H
$Wr&
$Wr&
$Wr&
3RZHUORVV
3HUPLVVLEOHUDWHGPRWRUFXUUHQWDQGVWDUWVSHUKRXU
6WDUWVSHUKRXU
ವ)RUQRUPDOVWDUWLQJ&/$66
5DWHGPRWRUFXUUHQW
,
0
UDPSXSWLPHV
ವ'XULQJRSHUDWLRQDIWHUVXFFHVVIXOVWDUWXSZLWKXQLQWHUUXSWHG
UDWHGRSHUDWLRQDOFXUUHQWr&DSSUR[
ವ'XULQJVWDUWLQJZLWKFXUUHQWOLPLWVHWWR
,
0
r&
0LQLPXPVHWWDEOHUDWHGPRWRUFXUUHQW
,
0
IRUWKHPRWRURYHUORDGSURWHFWLRQ
5:
$
$
$
$
:
:
$
bbK
%
'
&
$
5:
5:
5: 5: 5: 5: 5: 5: 5: 5: 5: 5:
5:RSWLRQDOIDQ
'LDJUDP%
Switching frequency of 3RW40 with standalone assembly:
50 1/h
Switching frequency factor for diagram B without a fan:
0.1
Switching frequency factor for diagram B with a fan
1)
:
1.6
Maximum permissible switching frequency:
Without fan
50 1/h x 0.1 = 5 1/h
With fan
1)
:
50 1/h x 1.6 = 80 1/h
1) Optional fan: 3RW49 28-8VB00