Specification Tables
*Specification table for Sterilisation: The definition of Fo/Po is the sterilisation/pasteurisation time in minutes required to destroy a stated number
of organisms with a known z at temperature T. For example, "F18/250" represents the time in minutes required to destroy a stated number of
organisms at a temperature of 250°F (121.11°C) with a z = 18 degrees F. F values are used to compare the sterilizing values of different proc-
esses, however, F values cannot be compared unless the z values are the same. When temperature is not specified (for example, F = 8.6) it
is understood that the temperature is 250°F (121.11°C); the subscript O (as in the term Fo = 7.4) is used to indicate that the z = 18 degrees F
and the temperature is 250°F (121.11°C).
Email (optional)
Setup email accounts to send the following: When an Alarm is triggered or an Email can be sent as a part
of an Event occurring, such as: Alarms - In/Out/Ack , Totaliser – Start, Stop or Reset, Digital Inputs – On,
Off or State change, TC Burnout – on a specific Analogue Input channel, Scheduled Events – Once, Inter-
val, Specific days, Month End.
Analogue Outputs
(Re-transmission Outputs)
(optional)
(not available for the
D200)
2 or 4 re-transmission outputs available for the
D300
Recorder and 2, 4, 6 or 8 re-transmission outputs
available for the
D400
Recorder; a pen drives each output. Analog inputs, totalised values or any mathe-
matical result can be re-transmitted.
Update Rate: 250 msec all channels Accuracy: ±0.1% 0-500
Ω
load, +/-0.25% 500
Ω
1K
Ω
load
Type: 0 to 20 / 4 to 20 mA Maximum Load Resistance: 1000 Ohms
Resolution: 0.002% Isolation: 300VAC
Health Watch/Maintenance
Capability (optional)
The recorder keeps track of important “life actions” for improved diagnostics and preventative mainte-
nance notification. Including Powered On, Last powered On, Time On since power up, Total On time, Total
Off time, Longest Off time, Lithium cell life, Backlight life left at 100% brightness, Hi/Lo CJC value (Hi & Lo
temps), Analogue In last factory/user cal, Relay operations, last configuration change.
Agency Approval (optional)
CSA (Optional) CSA22.2-No.1010.1-2004 Certificate Number 211230. UL (Optional) ANSI/UL61010-1-
2004 File # 201698. FM Class 1 Division 2 (optional). FM not available for the
D200
Extended Security System
(ESS) (optional)
Provides full support for 21 CFR Part 11. Includes features for entry of unique User ID’s and associated
passwords, timeout on inactivity (1 to 10 min.), password expiration (1 to 365 days), up to 50 users, pass-
word re-entry lock out for incorrect entry of password more than 3 times, no re-use of passwords (pro-
grammable 4 to 12 times), traceability by user name
Totaliser/Sterilisation*
(optional)
One totaliser per pen. Totaliser value must be assigned to a pen for display and storage. Multiple totalisa-
tions (Maths option) are possible with the use of extra pens (option). Reset may be manual or pro-
grammed (Event option). Totalisation values are ten digits plus exponent.
Each pen can be totalised according to the Fo or Po sterilisation* function at 250 °F (121.11°C). The
Standard Reference Temperature and Thermal Resistance (Z Value) are fully adjustable values of X, Y, W
and V. Start temp, Reference temp and Z factor are all user defined, allowing support for many different
types of sterilisation applications.
Batch (optional)
The Batch function allows the user to segment portions of data for further analysis. Batch enhances the
management of data collected in non-continuous process, known as batch processing.
Print Support (optional)
Enables the printer option to print from various Status screens using a basic USB standard PCL (Printer
Command Language) printer.
Math Algorithms (optional)
All analog input channels have a math expression text block. This is a fully user programmable 100 char-
acter free form math expression for each pen. Math calculations available on all pens, one per input plus
16 extra pens for the
D300
, 48 extra pens for the
D400
recorder. and 12 extra pens for the
D200
. Scripting
maths includes conditions and multi-line scripting in pen maths expressions. Allow functions, permanent
variables, constants and timers. 500 characters maximum. (Scripting is not available on the
D200
)
Miscellaneous
Optional customer ID Tagging (3 lines of up to 22 characters each line)
Specification Environmental and Operating Conditions
Parameter
Reference
Rated
Extreme
Transport & Stor-
age
Ambient Temperature
67 °F to 77 °F
19 °C to 25 °C
32 °F to 122 °F
0 °C to 50 °C
32 °F to 122 °F
0 °C to 50 °C
14 °F to 140 °F
–10 °C to 60 °C
Relative Humidity (%RH)
50 to 65*
10 to 90*
5 to 90*
5 to 95*
Vibration
Frequency (Hz)
Acceleration (g)
0
0
0 to 70
0.1
0 to 100
0.2
0 to 100
0.5
Specification Options
Summary of Contents for SIREC D200
Page 2: ......
Page 176: ...170 43 TV 25 35 GLO Iss 4 Dec 06 UK A5E01001767 04 Firmware Credit System ...
Page 222: ...216 43 TV 25 35 GLO Iss 4 Dec 06 UK A5E01001767 04 ...
Page 238: ...232 43 TV 25 35 GLO Iss 4 Dec 06 UK A5E01001767 04 ...
Page 258: ...252 43 TV 25 35 GLO Iss 4 Dec 06 UK A5E01001767 04 ...
Page 270: ...264 43 TV 25 35 GLO Iss 4 Dec 06 UK A5E01001767 04 ...
Page 274: ...268 43 TV 25 35 GLO Iss 4 Dec 06 UK A5E01001767 04 Modbus Function Codes ...
Page 284: ...278 43 TV 25 35 GLO Iss 4 Dec 06 UK A5E01001767 04 ...
Page 285: ......