3. Warm up the labyrinth sealing ring. Push the labyrinth sealing ring to approx. 3 mm before
the bearing cover before the paint or adhesive cures on the set screws.
3 mm
Figure 9-5
Position the set screws for the labyrinth sealing ring on the outer bearing cover
4. Locate the labyrinth sealing ring in position by screwing the set screws in. Check that the tips
of the set screws engage with the keyway with a short axial movement.
The correct axial position is obtained when the locating setscrews screwed into the keyway
engage.
9.2.4
Seal the motor
Extreme caution and attention to cleanliness are vital to installation.
● Clean all bare joints between parts such as housings, bearing shields and bearing bushes
etc., and remove old sealant material.
● Smear bare joints between parts with non-hardening, permanently flexible sealant, such as
"Hylomar M". Follow the manufacturer's application and safety instructions when doing this.
● Check all sealing elements, such as those on the terminal boxes, for elasticity, aging or
damage, and renew them if they are no longer effective.
Maintenance
9.2 Corrective Maintenance
SIMOTICS FD 1LH1
Operating Instructions 01/2019
139
Summary of Contents for SIMOTICS FD 1LH1
Page 2: ...23 01 2019 19 26 V11 01 ...
Page 28: ...Description SIMOTICS FD 1LH1 28 Operating Instructions 01 2019 ...
Page 122: ...Operation 8 10 faults SIMOTICS FD 1LH1 122 Operating Instructions 01 2019 ...
Page 140: ...Maintenance 9 2 Corrective Maintenance SIMOTICS FD 1LH1 140 Operating Instructions 01 2019 ...
Page 162: ...Disposal 11 5 Disposal of components SIMOTICS FD 1LH1 162 Operating Instructions 01 2019 ...
Page 164: ...Service and Support SIMOTICS FD 1LH1 164 Operating Instructions 01 2019 ...
Page 168: ...Quality documents SIMOTICS FD 1LH1 168 Operating Instructions 01 2019 ...