See also
Regreasing intervals and types of grease for operating roller bearings (Page 127)
Stoppages (Page 113)
Transport (Page 40)
7.5
Setting the automatic regreasing system
The relubrication is performed depending on the external voltage present at the regreasing
system.
● Prior to commissioning, set the time interval and the relubrication quantity at the automatic
regreasing system.
● Observe the operating instructions for the regreasing system for its operation and the
replacement of the grease cartridges.
See also
Interlock circuit for the automatic regreasing system (option) (Page 37)
7.6
Setpoint values for monitoring the bearing temperature
Prior to commissioning
If the machine is equipped with bearing thermometers, set the temperature value for
disconnection on the monitoring equipment before the first machine run.
Table 7-1
Set values for monitoring the bearing temperatures before commissioning
Set value
Temperature
Alarm
115 °C
Shutting down
120 °C
Normal operation
Determine the maximum operating temperature of the bearings T
operation
taking into account the
temperature, bearing load and influences of the plant on the motor in °C. Set the values for
shutdown and warning corresponding to the operating temperature T
op
.
Table 7-2
Set values for monitoring the bearing temperatures
Set value
Temperature
Alarm
T
operation
+ 5 K ≤ 115 °C
Shutting down
T
operation
+ 10 K ≤ 120 °C
Start-up
7.5 Setting the automatic regreasing system
SIMOTICS FD 1LH1
Operating Instructions 01/2019
101
Summary of Contents for SIMOTICS FD 1LH1
Page 2: ...23 01 2019 19 26 V11 01 ...
Page 28: ...Description SIMOTICS FD 1LH1 28 Operating Instructions 01 2019 ...
Page 122: ...Operation 8 10 faults SIMOTICS FD 1LH1 122 Operating Instructions 01 2019 ...
Page 140: ...Maintenance 9 2 Corrective Maintenance SIMOTICS FD 1LH1 140 Operating Instructions 01 2019 ...
Page 162: ...Disposal 11 5 Disposal of components SIMOTICS FD 1LH1 162 Operating Instructions 01 2019 ...
Page 164: ...Service and Support SIMOTICS FD 1LH1 164 Operating Instructions 01 2019 ...
Page 168: ...Quality documents SIMOTICS FD 1LH1 168 Operating Instructions 01 2019 ...
Page 173: ......