Appendix
A.3 Command and acknowledgement frames
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
333
A.3.7
KILL-TAG
The transponder is permanently deactivated.
Table A- 17 Command
Byte
0, 1
2, 3
4
5
6, 7
8
9
10
11
Mean-
ing
DBL
SN
CC
CI
TDB
DBN_H
DBN_L
DBL
--
Value
78
--
'j'
'U'
1
0
1
--
0
Byte
12
13
14, 15
16, 17
18 ... 21
22, 23
24, 25
26
27 ... 88
Mean-
ing
SOURCE --
--
--
PSWD
--
--
IDLENGT
H
EPC-ID
Value
0
0
0
0
0
0
0
--
--
Table A- 18 Reply
Byte
0, 1
2, 3
4
5
6, 7
8
9
10
Meaning
DBL
SN
CC
STATUS
TDB
DBN_H
DBN_L
DBL
Value
0
--
'j'
xx
1
--
1
0
Table A- 19 Description of the bytes
Byte
Description
12
Reserved (value = 0)
18, 19
Password for transponder access:
•
0x00 = no password
26
Length of the EPC ID:
•
0x00 = not addressed
27 ... 88
Buffer for up to 62 bytes EPC-ID