Programming via Rockwell controller
9.5 Programming add-on instructions
SIMATIC RF650R/RF680R/RF685R
172
Configuration Manual, 03/2018, C79000-G8976-C386-06
Table 9- 13 Explanation of the "Read_EPC_Mem" block
Parameter
Data type
Default values
Description
LEN_DATA
DINT
W#16#0
Length of the EPC memory to be read
out (1 ... 62 bytes)
LEN_ID
SINT
B#16#0
Length of the EPC-ID/UID
Default value: 0x00 ≙
unspecified
single tag access (RF680R, RF685R)
EPCID_UID
SINT[62]
0
Buffer for up to 62 bytes EPC-ID, 8
bytes UID or 4 bytes handle ID.
•
2 - 62-byte EPC-ID is entered at
the start of the buffer (length is set
by "LEN_ID")
•
8-byte UID is entered at the start
of the buffer ("LEN_ID = 8")
•
4-byte handle ID must be entered
in the array element [5]-[8]
("LEN_ID = 8")
Default value: 0x00 ≙ unspecified
single tag access (RF620R, RF630R,
RF640R)
IDENT_DATA
SINT[10]
0
Data buffer in which the read EPC
memory data is stored.
Note.
When necessary a byte/array of any
size can be transferred to this parame-
ter. Note that the array must be ≥ 10
bytes long (e.g. "SINT[12400]").