Programming via XML interface
10.3 XML commands
SIMATIC RF650R/RF680R/RF685R
232
Configuration Manual, 03/2018, C79000-G8976-C386-06
Parameter
Type
Values
Description
value_tagID
Hexadecimal
value
0...9, A...F
--
EPC-ID in "RAW Hex Data Format".
Example of a 96-bit EPC-ID:
3005FB63AC1F3681EC880468
For additional information, refer to the
"EPC Global Specification".
value_tagPC
Hexadecimal
value
0...9, A...F
--
Optional
Tag PC (Protocol Control)
16-bit value represented by four hexa-
decimal characters.
Example:
The value "1234" corresponds to the
binary value "0001.0010.0011.0100".
value_utcTime
Time
--
Optional
UTC time stamp (Universal Time Co-
ordinated) in ISO 8601 format:
yyyy-MM-ddTHH:mm:ss.fffzzz
e.g.: 2009-12-24T18:34:56.929+00:00.
value_
antennaName
Fixed values
Antenna01
Antenna02
Antenna03
Antenna04
Optional
Name of the antenna
value_rSSI
Decimal value
0...9
0...255
Optional
Largest measured RSSI value
value_channel
Decimal value
0...9
1...50
Optional
Channel number on which the tran-
sponder was detected.
value_power
Decimal value
0...9
0, 5.00...33.00
Optional
Used radiated power of the antenna in
[dB]
Increment: 0.25 dB
value_polarization Fixed values
Default
Circular
Linear_vertical
Linear_horizontal
All
Optional
Polarization of the antenna
Currently, this parameter can only be
set for the internal antenna of the
RF685R.