Configuring with the WBM
7.3 The menu items of the WBM
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
105
Roles
In the "Roles" area, you can assign roles to the user profile. Click the relevant check box to
assign the required roles to the user profile. The "Administrator" role has all read/write rights
●
Users
Restricted user profile with read/write rights. As "User", you cannot create new user
profiles or edit other user profiles. In addition to this, as the "user", you cannot write to the
reader in the "Run" reader status.
●
Administrator
User profile with all read/write rights
●
OPC UA
Restricted user profile with OPC UA rights. As an "OPC UA" user you can only log on to
an OPC UA connection. This role has no rights whatsoever in the WBM and it cannot be
used to log on to the WBM.
Click the "Save" button to save the changes and to create the new user profile.
Note
Restrictions when transferring the configuration
Note that as a "user", you can only transfer changes when the reader is in the "Idle" status.
As an "administrator" you can also transfer changes when the reader is in the "Run" status.
The following table provides you with an overview of the menu items that are restricted for
the "User" role:
Table 7- 31 Restrictions for the "User" role
Menu items
Restrictions
Start page
•
Restricted:
Input boxes cannot be filled.
•
No operator control is possible in the "Run" reader status.
Settings
Adjust antennas
•
No operator control is possible in the "Run" reader status.
Detect activation power
•
No operator control is possible in the "Run" reader status.
Diagnostics
Tag monitor
•
No operator control is possible in the "Run" reader status.
Log
•
Restricted:
The log cannot be reset.
Edit transponder
•
No operator control is possible in the "Run" reader status.
User management
•
Restricted:
Changing your own password.
System
•
No operator control is possible in the "Run" reader status.