Programming via XML interface
10.3 XML commands
SIMATIC RF650R/RF680R/RF685R
236
Configuration Manual, 03/2018, C79000-G8976-C386-06
Parameter
Type
Values
Description
value_
antennaName
Fixed values
Antenna01
Antenna02
Antenna03
Antenna04
Optional
Name of the antenna
value_rSSI
Decimal value
0...9
0...255
Optional
RSSI value
value_channel
Decimal value
0...9
1...50
Optional
Channel number on which the tran-
sponder was detected.
value_power
Decimal value
0...9
0, 5.00...33.00
Optional
Used radiated power of the antenna in
[dB]
Increment: 0.25 dB
value_polarization Fixed values
Default
Circular
Linear_vertical
Linear_horizontal
All
Optional
Polarization of the antenna
Currently, this parameter can only be
set for the internal antenna of the
RF685R.
value_
commandRetry
Decimal value
0...9
0...65535
Optional
Number of times the reader repeated
commands attempting to obtain correct
data.
"0" corresponds to no attempt.
The maximum number of attempts is
set using the WBM.
value_airRetry
Decimal value
0...9
0...65535
Optional
Number of times the reader repeated
air interface commands attempting to
obtain correct data.
"0" corresponds to no attempt.
The maximum number of air interface
commands is specified in the reader
firmware and cannot be modified.
value_
filterDataAvailable
Fixed values
True
False
Optional
Indicates whether or not a filter criteri-
on was received.
•
True:
No problem All the data was read
or there was no filter set.
•
False:
Data could not be read.