Programming via SIMATIC controller
8.6 Programming the Ident profile
SIMATIC RF650R/RF680R/RF685R
142
Configuration Manual, 03/2018, C79000-G8976-C386-06
8.6.4
Commands
Table 8- 22 PHYSICAL-READ
CMD OFFSET
BUFFER
LEN_
DATA
ADR_TAG CHAINED EPCID_
UID
LEN_ID MEM_
BANK
PSWD
IDENT_
DATA
0x70 Offset in
the
"RXREF"
receive
buffer
Length
of re-
ceived
data
Address
on the
tran-
sponder
True =
chained
False =
not
chained
Buffer for up to
62 bytes EPC-ID
2 - 62-byte EPC-
ID is entered at
the start of the
buffer (length is
set by "LEN_ID")
Default value:
0x00 ≙ unsp
eci-
fied single tag
access
Length of
the EPC-
ID (2-62
bytes)
0x00 ≙
unspeci-
fied sin-
gle tag
access
Memory
bank
•
0x00 ≙
reserved
•
0x01 ≙
EPC
•
0x02 ≙
TID
•
0x03 ≙
USER
Pass-
word
0x00 ≙
no pass-
pass-
word
Read data
Table 8- 23 PHYSICAL-WRITE
CMD OFFSET
BUFFER
LEN_
DATA
ADR_TAG CHAINED EPCID_
UID
LEN_ID MEM_
BANK
PSWD
IDENT_
DATA
0x71 Offset in
the
"TXREF"
send
buffer
Length
of the
data to
be writ-
ten
Address
on the
tran-
sponder
True =
chained
False =
not
chained
Buffer for up to
62 bytes EPC-ID
2 - 62-byte EPC-
ID is entered at
the start of the
buffer (length is
set by "LEN_ID")
Default value:
0x00 ≙ unsp
eci-
fied single tag
access
Length of
the EPC-
ID (2-62
bytes)
0x00
≙
unspeci-
fied sin-
gle tag
access
Memory
bank
•
0x00 ≙
reserved
•
0x01 ≙
EPC
•
0x02 ≙
TID
•
0x03 ≙
USER
Pass-
word
0x00 ≙
no pass-
pass-
word
Data to be
written
Table 8- 24 READER-STATUS
CMD
OFFSETBUFFER
ATTRIBUTES
CHAINED
IDENT_
DATA
0x74
Offset in the "RXREF"
receive buffer
Identifier of the status
mode "0x89"
True = chained
False = not chained
Received status data
You will find the data struc-
ture of the status mode in the
section "Reader_Status
(Page 121)".