Configuration parameters (CFG)
5.12 CFG14: Reserved
RF290R
38
Configuration Manual, 09/2014, C79000-G8976-C377-01
5.12
CFG14: Reserved
The configuration block CFG14 is reserved for later use.
Byte
0
1
2
3
4
5
6
Content
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
-
-
-
-
-
-
-
Byte
7
8
9
10
11
12
13
Content
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
-
-
-
-
-
-
-
5.13
CFG15: Antenna multiplexing
The parameters in CFG15 are used to configure multiplexing of antennas in the automatic
mode of the reader in conjunction with an antenna multiplexer ID ISC ANT.MUX.
Byte
0
1
2
3
4
5
6
Content
MUX-MODE
OUTPUT-
CHANNELS
MUX-VALID-TIME-ANT
0x00C8
0x00
Default
0x00
0x04
0x00C8
-
-
Byte
7
8
9
10
11
12
13
Content
0xC8
0x00C8
0x00C8
0x00
INPUT-
CHANNELS
Default
-
-
-
-
0x01
Name
Description
MUX-
MODE
Activates or deactivates multiplexing and specifies when the next output will be selected.
Bit
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
0
MUX
switching
condition
Multi-
plexing
Function
Description
Multiplex-
ing
•
b0 deactivate
•
b1 activate
MUX
switching
condition
Specifies when the next output will be selected.
•
b0 no response (if communication on the RF interface has ended)
•
b1 reserved