Configuration parameters (CFG)
5.9 CFG11: Read mode - read data
RF290R
32
Configuration Manual, 09/2014, C79000-G8976-C377-01
Name
Description
TR-DATA Selection of data types for the read operation
Bit
7
6
5
4
3
2
1
0
Function Expansion
-
TIMER
ANT
Byte order
DB
EAS
DB
SNR
Function
Description
SNR
•
b0 no serial number is saved
•
b1 serial number is saved
DB
•
b0 no data block number is saved
•
b1 data block number is saved
EAS
(only I-
Code SLI)
•
b0 no EAS function
•
b1 executes EAS command
Byte order
DB
•
b0 MSB first
•
b1 LSB first
ANT
•
b0 the number of the antenna is not saved
•
b1 the number of the antenna (1...8) where the transponder was identified is saved
TIMER
•
b0 no internal system time
•
b1 internal system time is active
Notes:
•
The internal system time is not a real-time clock (RTC) and the accuracy cannot be guaranteed.
•
EAS and simultaneous reading of serial numbers and data blocks is possible.
TR-DATA-
2
Selection of data types for the read operation
Bit
7
6
5
4
3
2
1
0
Function
-
-
-
ANT_EXT
-
-
-
-
Function
Description
ANT_Ext Antenna extended
•
b0 no RSSI
•
b1 antenna number with RSSI
Note:
If the extended antenna is activated, the bit for the number of the antenna must be deactivated.
TR-DATA-
3
Selection of data types for the read operation
Bit
7
6
5
4
3
2
1
0
Function
-
-
-
READ_C
OMPLET
E_
BANK
-
-
-
COM-PRE
FIX