Configuration parameters (CFG)
5.14 CFG16: Reset persistency
RF290R
Configuration Manual, 09/2014, C79000-G8976-C377-01
39
Name
Description
OUTPUT-
CHAN-
NELS
Specifies the number of output channels used for multiplexing.
Function
Description
OUTPUT-
CHAN-
NELS
•
b001 1 antenna
•
b010 2 antennas
•
b011 3 antennas
•
b100 4 antennas
•
b101 5 antennas
•
b110 6 antennas
MUX-
VALID-
TIME-ANT
As soon as this time has expired (value x 5 ms), the next antenna output is selected.
If "no response" is selected for the MUX switching condition, the reader switches from the active antenna to
the next antenna if there is no response from any transponder of the active antenna. If the transponder com-
munication time of the active antenna exceeds MUX-VALID-TIME-ANT, the transponder communication of the
active antenna is stopped and the reader switches to the next antenna. If "fixed" is selected as the switching
condition, the switch to the next channel is always within this period.
INPUT-
CHAN-
NELS
Specifies the number of inputs
Function
Description
INPUT-
CHAN-
NELS
•
b00 -
•
b01 1 input
•
b10 reserved
5.14
CFG16: Reset persistency
The parameters in CFG16 are used to configure the reader reset times for the persistence
flags of the transponders. The times for resetting the persistence flags are used by the
reader in the ISO host mode, "Scan Mode" and "Buffered Read Mode".
Byte
0
1
2
3
4
5
6
Content
0x00
0x00
PER-RESET-TIME
0x00
0x00
0x00
Default
-
-
0x0028
40 x 5 ms = 200 ms
-
-
-
Byte
7
8
9
10
11
12
13
Content
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
-
-
-
-
-
-
-