Protocols for the configuration of the reader
6.2 [0x81] Write Configuration
RF290R
44
Configuration Manual, 09/2014, C79000-G8976-C377-01
Name
Description
LOC
specifies the memory location of the configuration block
•
b0 RAM
•
b1 EEPROM
CFG-REC 14 byte long configuration block read from address CFGn in CFG-ADR
2)
For more information, refer to the section "Configuration parameters (CFG) (Page 21)".
Note
Error code 0x15
A read configuration from the EEPROM with reserved configuration blocks causes error
code 0x15.
6.2
[0x81] Write Configuration
With the "Write configuration" command, you change the configuration of the reader. To do
this, you write 14 byte long blocks to the configuration memory. For addressing you use
CFGn in the CFG-ADR byte. You will find a description of the parameters in the section
"Configuration parameters (CFG) (Page 21)".
Table 6- 3
Host
→ reader
Byte
1
2
3
4
5
6
7 ... 20
21, 22
Content
STX
MSB
LSB
ALENGTH
COM-ADR
[0x81]
CFG-ADR CFG-REC
CRC16
Default
0x02
-
-
-
-
-
-
-
Table 6- 4
Reader → host
Byte
1
2
3
4
5
6
7, 8
Content
STX
MSB
ALENGTH
LSB
ALENGTH
COM-ADR
[0x81]
STATUS
1)
CRC16
Default
0x02
-
-
-
-
-
-
1)
You will find further information in the Appendix (Page 103).
Name
Description
CFG-
ADR
2)
Bit
7
6
5
4
3
2
1
0
Function
LOC
0
CFGn: Address of the configuration block
Function
Description
CFGn
Memory address of the required configuration block