ISO 15693 host commands
9.2 Supported ISO 15693 host command for ISO 15693 transponders
RF290R
80
Configuration Manual, 09/2014, C79000-G8976-C377-01
Command code Function
Mode
Comment
-
-
not addressed addresses
Selection
-
0x01
Inventory
✓
-
-
-
-
0x02
Stay Quiet
✓
-
✓
-
-
0x22
Lock Multiple
Blocks
-
-
-
-
-
0x23
Read Multiple
Blocks
✓
✓
2)
✓
-
DB-SIZE = 4
0x24
Write Multiple
Blocks
1)
✓
✓
✓
-
DB-SIZE = 4
WR-OPTION =
0
0x25
Select
-
-
-
-
-
0x26
Reset to Ready
✓
✓
✓
-
-
0x27
Write AFI
-
-
-
-
-
0x28
Lock AFI
-
-
-
-
-
0x29
Write DSFID
-
-
-
-
-
0x2A
Lock DSFID
-
-
-
-
-
0x2B
Get System
Information
-
-
-
-
-
0x2C
Get Multiple
Block Security
Status
-
-
-
-
-
1) The WR-OPTION is set automatically by the reader if the WR-OPTION parameter in the "CFG4 transponder parameters"
is set to "00: specified automatically".
2) Reading a block in non-addressed mode is only possible if the "Read mode" parameter in the "CFG4 transponder pa-
rameters" is set to "b10: read multiple".
9.2.2
EM Microelectonics (EM4135)
Chip ID: 4h = 000100xx (bit 47 - 42 of UID)
Table 9- 7
Memory arrangement 38 × 8 bytes = 2432 bits
Number of blocks
36 (user range: 13 ... 48)
Block size
8 bytes
Command code Function
Mode
Comment
-
-
not addressed addresses
Selection
-
0x01
Inventory
✓
-
-
-
-
0x02
Stay Quiet
✓
-
✓
-
-
0x22
Lock Multiple
Blocks
✓
✓
✓
✓
WR-OPTION = 0