Description
The page contains the following:
● Enable SINEMA RC
– Enabled:
A connection to the configured SINEMA RC Server is established. These boxes cannot
be edited.
– Disabled:
The boxes can be edited. Any existing connection is terminated.
"Server settings" area
● SINEMA RC Address
Enter the IPv4 address or the FQDN (Fully Qualified Domain Name) of the SINEMA RC
Server.
● SINEMA RC Port
Enter the port via which the SINEMA RC Server can be reached.
"Server Verification" area
● Verification Type
– Fingerprint: The identity of the server is verified based on the fingerprint.
– CA certificate: The identity of the server is verified based on the CA certificate.
● Fingerprint
Only necessary with the setting "Fingerprint". Enter the fingerprint of the device. The
fingerprint is assigned during commissioning of the SINEMA RC Server. Based on the
fingerprint, the device checks whether the correct SINEMA RC Server is involved. You will
find further information on this in the Operating Instructions of the SINEMA RC Server.
● CA Certificate
Only necessary with the setting "CA Certificate". Select the CA certificate of the server used
to sign the server certificate. Only loaded CA certificates can be selected.
"Device Credentials" area
● Device ID
Enter the device ID. The device ID is assigned when configuring the device on the SINEMA
RC Server. You will find further information on this in the Operating Instructions of the
SINEMA RC Server.
● Device Password
Enter the password with which the device logs on to the SINEMA RC Server. The password
is assigned when configuring the device on the SINEMA RC Server. You will find further
information on this in the Operating Instructions of the SINEMA RC Server.
● Device Password Confirmation
Repeat the password.
Configuring with Web Based Management
4.3 "Wizard" menu
SCALANCE S615 Web Based Management
74
Configuration Manual, 11/2019, C79000-G8976-C388-08