Notification options
If the status of the digital input or a VPN tunnel (IPsec, OpenVPN, SINEMA RC) changes, the
device provides several options for notification on the "Events (Page 137)" page.
Type of notifica‐
tion
Di
gi‐
tal
In
VPN
tun‐
nel
Behavior if there is a status change
x
x
The device sends an e-mail. The e-mail contains the identification of the sending device, a
description of the cause of the alarm in plain language, and a time stamp.
Requirement:
● An SMTP server is set up.
● In "System > SMTP Client" the function is activated, a recipient and the IP address of the
SMTP server are configured.
Trap
x
x
The device sends an SNMP trap.
Requirement:
● "SNMPv1 traps" is enabled in "System > Configuration".
● In "System > Configuration > Traps" a recipient is configured to which the device sends the
SNMP traps.
Log table
x
x
The device writes an entry in the event log table. The content of the event log table is displayed
in "Information > Log Table".
Syslog
x
x
The device writes an entry to the Syslog server.
Requirement:
● A Syslog server has been set up.
● In "System > Syslog Client" the function is activated and the IP address of the Syslog server
is configured.
Fault LED
x
-
The fault LED lights up on the device.
Technical basics
3.5 Security functions
SCALANCE S615 Web Based Management
56