Image processing
4.2 Code verification
SIMATIC MV420 / SIMATIC MV440
70
Operating Instructions, 04/2013, A5E02371045-06
4.2.8.3
Standard report for ISO/IEC 15415
Field name (TAG)
Value
Verification type (Qt)
2
If the exposure settings do not comply with the
standard: C
Evaluation (Qs)
3 (Good), 2 (Fair) or 1 (Poor)
Overall grade (Q0)
4, 3, 2, 1 or 0
Reference decode grade (Q7)
4, 3, 2, 1 or 0
Contrast grade (Q1)
4, 3, 2, 1 or 0
Contrast (q1)
0 ... 100
Axial non-uniformity grade (Q2)
4, 3, 2, 1 or 0
Axial non-uniformity (q2)
0.00 ... 1.00
Grid non-uniformity grade (Q3)
4, 3, 2, 1 or 0
Grid non-uniformity (q3)
0.00 ... 1.00
Unused error correction grade (Q4)
4, 3, 2, 1 or 0
Unused error correction (q4)
0.00 ... 1.00
Fixed pattern damage grade (Q5)
4, 3, 2, 1 or 0
Modulation grade (Q6)
4, 3, 2, 1 or 0
Print growth X (q9)
-100 ... 100
Print growth Y (q9)
-100 ... 100
Cell size (q10)
0 ... 99.9 mil
Aperture (q12)
0, 4 ... 20 mil (0 corresponds to automatic)
ECCLevel (q14)
200
Height (q15)
0 ... 9.99 inches
Width (q16)
0 ... 9.99 inches
Angle (q17)
0 ... 360°
Summary of Contents for SIMATIC MV420
Page 2: ......
Page 418: ...Glossary SIMATIC MV420 SIMATIC MV440 416 Operating Instructions 04 2013 A5E02371045 06 ...
Page 423: ......